当前位置: 首页 > wzjs >正文

包头网站建设公司网站怎么让百度收录

包头网站建设公司,网站怎么让百度收录,html5自建网站,前端开发 wordpress主题Benchmarks | Storage Performance Council 一、SPC ​核心测试标准体系​ ​测试标准​​核心目标​​适用场景​​关键性能指标​​SPC-1​随机I/O负载性能OLTP、数据库、邮件服务器(高并发随机读写)IOPS、响应时间、ORT​SPC-2​大块顺序I/O吞吐性能…



Benchmarks | Storage Performance Council

一、SPC


核心测试标准体系

测试标准核心目标适用场景关键性能指标
SPC-1随机I/O负载性能OLTP、数据库、邮件服务器(高并发随机读写)IOPS、响应时间、ORT
SPC-2大块顺序I/O吞吐性能科学计算、视频点播(VOD)、大数据分析(连续数据流)吞吐量(MB/s)、响应时间
SPC-3混合负载与备份恢复性能文件系统备份、云存储、软件定义存储(SDS)带宽、恢复时间
SPC-1C/2C组件级性能(如SSD、HBA)单设备或小型子系统评估(如SPC-1C针对SSD可持续性能)IOPS、延迟、成本效能比

SPC SPECIFICATIONS

SPC BENCHMARK 1 (SPC-1) SPECIFICATION

The  SPC-1 version 3, retains the core capabilities and requirements of SPC-1 version 1, but includes support for data deduplication, and data compression, in addition to refining some of the workload attributes to bring the benchmark more in-line with modern storage system workloads. To assure a smooth transition to the new implementation of the SPC-1 workload, Test Sponsors are allowed to publish against either the version 1 or version 3 specification for the time being, though version 1 results are not comparable to version 3 results. 

The current and previous versions of the SPC-1 specification, which includes the SPC-1/E Energy Extension, are listed below. The "Effective Date" designates the date on which a given specifcaiton revision replaces its predecessor. Benchmark results may be released to be compliant with a version of the specification that has an "Effective Date" in the future.

Questions and comments concerning the specification may be sent to the SPC Administrator.

Version
(effective date)
Description/CommentsFormat
v3.10(01 January 2021)

A minor revision to clarify Physical Free Space.

PDF (1.84 MB)

v3.9(27 May 2020)
  • Creation of stand-alone Energy Extension (Clause 12)

  • Introduction of Glossary as Appendix C

  • Overhaul of Pricing requirements and reliance on SPC Pricing Guide (Clause 9)

  • Rework of Executive Summary format 

PDF (1.82 MB)

v3.8(28 October 2018)

Official release. Recent changes:

  • Correct SER calculation (2.7.4,10.7.8)
  • Update membership roster

PDF (1.55 MB)

v3.8(27 August 2018)

Identical to the official 3.8 release, but with change bars relative to v3.7.

PDF (1.58 MB)

v3.7(22 July 2018)

See "Document History" for a list of revisions. 

PDF (1.55 MB)

v3.6(15 February 2018)

See "Document History" for a list of revisions

PDF (1.55 MB)

v1.14(31 January 2017)

Version 1.0 of the SPC-1 benchmark has been retired, but the results are still visible on the SPC web site. The final revision of the version benchmark specification is retained to provide proper context for the review of those results.

PDF (1.18 MB)

SPC BENCHMARK 2 (SPC-2) SPC BENCHMARK 2/ENERGY EXTENSION (SPC-2/E) SPECIFICATION

The current and previous versions of the SPC-2 specification, which includes the SPC-2/E Energy Extension, are listed below. The "Effective Date" designates the date on which the current version replaces the previous version. Benchmark results may be released to be compliant with a version of the specification that has an "Effective Date" in the future.

Questions and comments concerning the specification may be sent to the SPC Administrator.

Version
(effective date)
Description/CommentsFormat
v1.8(01 January 2021)

This revision includes a general overhaul of the specification to bring it more in line with the approaches taken with SPC-1. Most of the changes are organizational only, with a few exceptions:

  • Updated full disclosure organization to match modern FDRs
  • New Executive Summary format
  • Simplified storage hierarchy

PDF (1.26 MB)

v1.7(15 August 2017)

See "Document History" (page 2) for a list of revisions

PDF (2.17 MB)

v1.6(15 January 2017)

See "Document History" (page 2) for a list of revisions

PDF (2.21 MB)

PDF (2.25 MB)

SPC BENCHMARK 1C (SPC-1C) SPC BENCHMARK 1C/ENERGY EXTENSION (SPC-1C/E) SPECIFICATION

The current and previous versions of the SPC-1C specification, which includes the SPC-1C/E Energy Extension, are listed below. The "Effective Date" designates the date on which the current version replaces the previous version. Benchmark results may be released to be compliant with a version of the specification that has an "Effective Date" in the future.

Questions and comments concerning the specification may be sent to the SPC Administrator.

Version
(effective date)
Description/CommentsFormat
v1.5(12 May 2013)

See "Document History" (page 3) for a list of revisions

PDF (1.01 MB)

v1.4(18 November 2012)

See "Document History" (page vi) for a list of revisions

PDF (782.59 KB)

SPC BENCHMARK 2C (SPC-2C) SPC BENCHMARK 2C/ENERGY EXTENSION (SPC-2C/E) SPECIFICATION

The current and previous versions of the SPC-2C specification, which includes the SPC-2C/E Energy Extension, are listed below. The "Effective Date" designates the date on which the current version replaces the previous version. Benchmark results may be released to be compliant with a version of the specification that has an "Effective Date" in the future.

Questions and comments concerning the specification may be sent to the SPC Administrator.

Version
(effective date)
Description/CommentsFormat
v1.4(12 May 2013)

See "Document History" (page 2) for a list of revisions

PDF (1.10 MB)

v1.3(18 November 2013)

See "Document History" (page 2) for a list of revisions

PDF (908.50 KB)

SPC POLICIES AND PROCEDURES

The SPC Policies and Procedures define the day-to-day operations for the Storage Performance Council. This is the definitive source of information about meetings, benchmark development, results publication, technical subcommittees, and all other operational aspects of the council. If you have any questions about this or any other administrative documents, please contact the executive director.

Version
(effective date)
Description/CommentsFormat
v5.1(01 November 2022)

Extend lifecycle for benchmark extensions

Introduce more flexible dues payment schedule

PDF (458.99 KB)

v5.0(01 November 2020)

Rework Policies to align with Bylaws version 3.0

PDF (461.03 KB)

v4.12(01 November 2019)

Changes approved at the October 2019 Face-to-Face meeting:

  • Clarify result withdrawal for non-payment (10.3.2.6)

  • Reduce the number of face-to-face meetings per year (8.1)

  • Replace “Public Review” with “Peer Review” for consistency

PDF (590.51 KB)

v4.11(01 October 2019)

Changes in this revision:

  • Non-member results are assumed to be inactive upon status renewal.

PDF (585.02 KB)

PDF (669.22 KB)

v4.10(01 January 2019)

Change Summary:

  • Council business to be conducted in English
  • Membership applications require an English-language web site
  • Define the SC responsibility for membership application review
  • Define benchmark retirement process

PDF (397.78 KB)

PDF (429.64 KB)

v4.9(01 February 2018)

Version 4.9 defines Benchmark Extensions, and related policies.

PDF (229.07 KB)

v4.9(01 February 2018)

Identical to the official release of version 4.9, but with change bars relative to version 4.8

PDF (231.95 KB)

v4.8(15 July 2017)

Changes in this revision:

  • Rename Administrator to Executive Director
  • Pro-rate any dues increase related to a change in membership class
  • Creation of SPC Web Editor

PDF (220.15 KB)

SPC BYLAWS

Version
(effective date)
Description/CommentsFormat
v3.0(10 November 2020)

Reorganize Board and Steering Committee

PDF (225.59 KB)

v2.2(18 July 2017)
  • Define Emeritus membership status

PDF (114.99 KB)

ANTITRUST POLICY

The Storage Performance Council was formed to provide benefit for the storage industry and its customers. As set forth in Article I of the Bylaws, it is the policy of the SPC to comply fully with the antitrust laws of the United States and similar foreign competition laws applicable to the SPC’s activities. It is expected that all company member
representatives involved in SPC activities, all SPC contractors, all SPC auditors, and any guests invited to participate in any SPC activity will take all measures necessary to comply with antitrust and competition laws.

Version
(effective date)
Description/CommentsFormat
v1.0(01 December 2016)

Initial release

PDF (43.47 KB)

SPC PRICING GUIDE

This specification provides a uniform approach to the composition and pricing of storage configurations that may be applied to all SPC benchmarks. It is intended to:

  • Clarify the basis for pricing-related calculations and disclosures;
  • Define the terms and constraints related to pricing within SPC benchmark disclosures;
  • Provide a uniform framework that can be applied to all SPC benchmarks without constraining the development of novel benchmark methodologies;
  • Simplify the process of benchmark and benchmark extension development.
Version
(effective date)
Description/CommentsFormat
v1.0(08 June 2020)

Initial release (modeled on SPC-1 v3.8 content)

PDF (410.33 KB)

Storage Performance Council Logo

PO BOX 3504,
REDWOOD CITY, CA 94064-5304

TEL: (650) 556-9384

FAX: (650) 206-5354

Footer Menu

  • HOME
  • BENCHMARKS
  • ABOUT SPC
  • SPECIFICATIONS
  • MEMBERSHIP
  • NEWS
  • LINKS
  • CONTACT US
  • SUPPORT

Copyright © 2017 Storage Performance Council. All rights reserved. Privacy Policy

Bitnami

二、测试系统理论基础

  1. 负载模型设计

    • ASU(应用存储单元)​​:划分三类逻辑存储区域,模拟真实业务数据分布:
      • ASU1(数据存储,45%空间)​​:59.6%负载,含4类I/O流(随机读写+顺序读)
      • ASU2(用户存储,45%空间)​​:12.3%负载,含3类I/O流(读少写多)
      • ASU3(日志存储,10%空间)​​:28.1%负载,纯顺序写
    • BSU(事务扩展单元)​​:动态调整I/O请求规模,模拟业务压力变化。
  2. I/O流参数规范
    每类I/O流定义五维属性:

    | 参数          | 选项示例                          |
    |---------------|-----------------------------------|
    | 传输块大小     | 4K/8K/16K/32K/64K(混合SMIX流)   |
    | 读写比例       | 1:1(ASU1)、3:7(ASU2)、0:100(ASU3) |
    | 访问模式       | 随机(Uniform)、顺序(Incremental) |
    | 访问区域       | 全地址空间或局部热点(如0.15-0.2) |
    | 访问强度       | 负载权重系数(如ASU1-Stream2占28.1%)|

三、测试规则与执行序列

  1. SPC-1测试流程​(分阶段强制验证):

    • Metrics测试
      • 持续性测试​(≥8小时):满负载稳定性验证(波动需<5%)
      • IOPS测试​(10分钟):记录峰值性能(平均延迟≤30ms)
      • 响应时间坡度测试​:负载从100%阶梯降至10%(95%/90%/80%/50%/10%)
    • Repeat测试​(×2次):重复Metrics阶段,结果偏差需<5%
    • Persistence测试​:断电重启验证数据一致性
  2. SPC-2测试流程​(顺序负载):

    • LFP(大文件处理)​​:顺序读/写/混合(1MB/256KB块)
    • LDQ(大型数据库查询)​​:全表扫描(1MB/64KB块)
    • VOD(视频点播)​​:多流并发读取

四、核心测试算法

  1. 性能指标算法

    • 总体响应时间(ORT)​​:基于负载阶梯的延时方差计算
      ORT = \sqrt{\frac{\sum_{i=1}^{n}(RT_i - \overline{RT})^2}{n-1}}
    • 可持续IOPS​:长稳测试中剔除首尾10%数据后的均值
  2. 负载生成算法

    • 随机地址生成​:均匀分布(Uniform)、局部热点(R1/W1)
    • 动态强度调整​:按BSU单位线性缩放请求并发量

五、测试模型代码设计

SPC未公开完整源码,但规范中明确关键逻辑(以伪代码示例):

# ASU1 Stream 3 (SMIX混合负载) 实现
def generate_smix_io():block_sizes = [4, 8, 16, 32, 64]  # KBweights = [0.35, 0.30, 0.20, 0.10, 0.05]  # 出现概率size = np.random.choice(block_sizes, p=weights) * 1024  # 按权重选块大小address = calc_address(mode="incremental", zone=(0.2, 0.7))  # 在20%-70%地址段顺序访问return IO_Request(size, address, op="READ")  # 100%读操作

六、测试系统设计哲学

  1. 真实性与可重复性

    • 禁用缓存优化(长稳测试规避缓存命中)
    • 强制公开完整环境配置(硬件型号、固件版本、网络拓扑)
  2. 扩展性演进

    • SPC-1 Gold Star​:新增五项能力验证(数据缩减/快照/加密/复制/无损升级)
    • 6G融合场景​:通感算一体架构支持实时边缘分析(如无人机避障)

通过分层负载模型​(ASU/BSU)、多阶段验证​(长稳/重复/断电)和开放审计,SPC为存储系统提供了业界公认的“性能标尺”。开发者可通过SPC官网获取测试工具包与规范文档,实现私有化部署验证。

http://www.dtcms.com/wzjs/60974.html

相关文章:

  • abbs建筑网站百度官网认证申请
  • 泗水网站建设杭州seo推广排名稳定
  • php做的静态网站怎么加密十大经典广告营销案例
  • 简单企业网站深圳网络营销模式
  • 哪些平台可以建立网站青岛seo公司
  • 百度云wordpress怎么搭建北京seo网络优化招聘网
  • 手机网站制作建设seo视频教程百度云
  • wordpress全站公告广点通投放平台
  • 网站建设需要的文案品牌维护
  • 谷歌网站推广软件站长网站
  • 外贸 网站 模板磁力bt种子搜索神器
  • 自己学网站建设北京网站优化公司哪家好
  • 网站建设执行风险下载关键词推广软件
  • 网站建设软件有哪些网站建设的流程及步骤
  • 网站内容和备案不一地推网app推广平台
  • 西宁网站seo公司网络赚钱推广
  • wamp网站开发扬州seo推广
  • 线上推广员是做什么的关键词自动优化工具
  • 北京服装设计公司西安企业seo
  • 武汉市做网站的公司免费投放广告的平台
  • 网站开发语言分类b站视频推广网站2023
  • 手机网站在后台怎么做编辑想要网站推广版
  • 给政府做网站的申请seo入门书籍
  • 嘉兴市做网站优化投稿网站
  • 海南做网站的google官方入口
  • 自己做的网站出现左右滑动条品牌推广策略包括哪些内容
  • 做的好的ppt下载网站网址大全浏览器app
  • 网站建设教育类旧式网站近一周新闻热点事件
  • 网站404页面的作用谷歌seo优化
  • 网站建设diy服务器域名查询